@@ -31,9 +31,17 @@ matches and the node reconnects on its own.
identity file, so it re-enrols onto the same node id with its accelerators, storage roots and
history intact. Enrolment revokes the previous credential automatically.
If the node's identity volume is still present and an administrator can install a replacement
credential directly, open the node detail and use **Rotate node credential**. Rotation revokes the
old key immediately. Replace `/data/state/node-credential` with the one-time value and recreate the
agent before expecting heartbeats or inventory to resume. The Console cannot install the value on
the node. If the identity volume is missing, use fresh enrolment instead.
**The credential is believed stolen.** Revoke it first
(`DELETE /api/v1/admin/hardware/nodes/{node_id}/credential`), then re-enrol. Revocation is
permanent: the old credential stays refused after re-enrolment.
permanent: the old credential stays refused after re-enrolment. If a replacement can be installed
immediately, the node detail's rotation action combines revocation and replacement; the old key is
still permanently refused.
**The identity file is also lost.** The agent enrols as a new node, because ModelForge genuinely
cannot tell it apart from different hardware. If the old identity is permanently superseded, use